WALVOIL VALVE MOUNTING INSTRUCTIONS
(See Page 3 for Valve Stand Mounting Instructions)
VALVE PLUMBING ASSEMBLY
Single Handle Controls shown.
Color Code Red - Rod End of Lift
Color Code Green - Head End of Bucket
Color Code Blue - Head End of Lift
Color Code Yellow - Rod End of Bucket
To the four metal
lines on loader
25H40124
(2) Male 45
0
Elbows
25H50807
Handle Assembly
Note: When the Bush Hog Valve is used in con-
junction with tractors having a PFC system
the valve Must be connected to the Tractor
Remotes.
Open Center
Plug
Closed Center
Plug
To
Pressure Outlet
To
Return Inlet
( See Note 1 Below )
Note 1: Use two (25H49867) 156” (5045, 6045) Hydraulic Hoses with 50051735 Single Handle.
Use two (25H50266) 120” (3545, 4045) Hydraulic Hoses with 50051736 Single Handle.
Note: This Valve is set for an Open Center Tractor Hydraulic System
When shipped. When attaching to tractors with Closed Center
Hydraulic Systems, A Closed Center Plug must be installed.
(A. Remove Open Center Plug.
(B. Installed the Closed Plug furnished with valve.
(C. Reinstall Open Center Plug into end of closed Center Plug.
VALVE STAND ASSEMBLY INSTRUCTIONS
Note: Must be mounted to Loader Bracket
before mounting Loader to Bracket.
VALVE SHORT MOUNT ASSEMBLY INSTRUCTIONS
Note: Must be mounted to Loader Bracket
before mounting Loader to Bracket.
Loader
Bracket
Mount Plate to Loader Bracket
(Bottom Hole)
(1) 1/2” x 3” Capscrew
(2) 1/2” Flatwashers
(1) 1/2” Lockwasher
(1) 1/2” Hex Nut
Mount Plate to Loader Bracket
(Top Hole)
(1) 1/2” x 2-3/4” Capscrew
(1) 1/2” Lockwasher
(1) 1/2” Hex Nut
50027309
Valve Mount Bracket
Mount Plate to Loader Bracket
(Bottom Hole)
(1) 1/2” x 3” Capscrew
(2) 1/2” Flatwashers
(1) 1/2” Lockwasher
(1) 1/2” Hex Nut
Mount Plate to Loader Bracket
(Top Hole)
(1) 1/2” x 2-3/4” Capscrew
(1) 1/2” Lockwasher
(1) 1/2” Hex Nut
Mount Tube to Valve Mount Bracket
(2) 1/2” x 3-1/4” Capscrews
(2) 1/2” Lockwashers
(2) 1/2” Hex Nuts
25H41158
(2) Spacers
(See Note 1)
50027313
Mount Plate
Loader
Bracket
Note 1: Place spacers inside mount plate to
replace mount tube.
Hoses Not
Shown for Clarity!
Hoses Not
Shown for Clarity!
Shield Not Shown for Clarity!
Hoses Shown Disconnected for Clarity!
Color Code Blue
Color Code Red
Color Code Yellow
Color Code Green
Page 3