OPTIONAL THERMOSTAT


A thermostat may help you maintain a constant house temperature
automatically. A millivolt thermostat is required. A fixed wall mount
or Breckwell’s hand held model can be used. The control panel can
be set up two ways to operate your stove in thermostat mode.

NOTE: YOUR THERMOSTAT SHOULD BE INSTALLED BY AN

AUTHORIZED DEALER OR SERVICE PERSON.

THERMOSTAT INSTALLATION

A MILLIVOLT THERMOSTAT IS REQUIRED.

Unplug stove from power outlet.

Remove control board from stove.

The two thermostat wires connect to the terminal block on the
lower left side of the back of the control board.

(See figure 24)

Insert the wires in the terminal side and tighten the two screws.

MODES

TO SWITCH BETWEEN ANY OF THE THREE MODES THE
STOVE MUST BE SHUT OFF, THE NEW MODE SELECTED, AND
THE STOVE RESTARTED.

MANUAL MODE

In this mode the stove will operate only from the control panel
as detailed in the “

OPERATION

” section of this owner’s

manual.


HIGH/LOW THERMOSTAT MODE

When engaged in this mode the stove will automatically switch
between two settings. When warm enough, it will switch to the
#1 or low setting. The room air blower will also slow to its
lowest speed.

The Heat Level Advance setting on the bar graph will stay
where it was initially set. When the house cools below the
thermostat setting, the stove will switch to the feed rate of the
heat level advance setting.


ON/OFF THERMOSTAT MODE

In this mode when the home is warm enough the stove will
shut off. The fans will continue to run until the stove cools.

When the home cools below the thermostat setting, the stove
will automatically restart and run at the last feed rate setting.



NOTE: When in “high/low” or “on/off” thermostat mode –

Do not operate the stove higher than the #3 setting.

Set damper control rod approximately ½” to ¾” out. This will
vary depending on elevation and weather conditions. Observe
stoves operation and adjust damper as necessary.