Installation 10 – Breckwell P22FSL User Manual
Page 10
INSERT INSTALLATIONS
Insert installations must be vented with 3” or 4” pipe. Pipe
may be single wall stainless steel flexible pipe. Vent may
terminate within chimney beyond a blanking plate or
extend to the chimney top. See “COMBUSTION AIR
SUPPLY” for outside air access information.
The fireplace and chimney should be cleaned thoroughly
before starting the installation. We suggest painting the
interior of particularly old and dirty fireplaces to seal any
odors. In zero-clearance fireplace installations, when the
fireplace opening is above the floor or raised hearth, the
adjustable “Breckwell P22 Z-C Legs” can be used to
bridge the gap between the hearth and stove bottom.
Refer to figure 14.
A.
ASSEMBLING THE FLASHING SET
Follow the instructions packaged with the P22 Flashing
set part C-P22-MED (refer to Figure 15).
FIGURE 14
FIGURE 15
INSTALLATION
10