Operation 14 – Breckwell P22FSL User Manual
Page 14
PANEL CONTROLS
(See Figure 22)
The blowers and automatic fuel supply are controlled from a panel on the left-hand side of the P22. The
control panel functions are as follows.
a.
ON/OFF SWITCH
•
When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will
stay on for at least 10 and up to 15 minutes, depending on when Proof of Fire is reached. The fire
should start in about 5 minutes.
•
The green light located above the On/Off button (in the On/Off box) will flash during the ignition
start-up period. (See figure 22)
•
The Feed Rate Advance is inoperable during the ignition start period. When the red light
continuously stays on the Feed Rate Advance can be adjusted to achieve the desired heat output.
NOTE: If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button
must be held down for 2 seconds.
b.
FUEL FEED SWITCH
•
When the “Fuel Feed” button is pushed and held down the stove will feed pellets continuously into
the burnpot.
•
While the stove’s auger system is feeding pellets the amber light (in the “Fuel Feed” box) will be
on. (See figure 22)
CAUTION: DO NOT USE THIS CONTROL DURING NORMAL OPERATION BECAUSE IT COULD
SMOTHER THE FIRE AND LEAD TO A DANGEROUS SITUATION.
c.
HIGH FAN SWITCH
•
The room air fan speed varies directly with the feed rate. The “HIGH FAN” switch overrides this
variable speed function. It will set the room air blower speed to high at any feed rate setting.
•
When the “HIGH FAN” button is pushed the room air fan will switch to its highest setting.
•
When this button is pushed again the room air fan will return to its original setting based on the
Feed Rate Advance setting.
d.
RESET TRIM
Different size and quality pellet fuel may require adjustment of the “1” feed setting on the Feed Rate
Advance bar graph. This is usually a one-time adjustment based on the fuel you are using. The
“RESET TRIM” button when adjusted will allow for 3 different feed rate settings for the #1 feed setting
only. To adjust simply push the “RESET TRIM” button while the stove is operating at setting “1” and
watch the bar graph.
•
When the “1” and “3” lights are illuminated on the bar graph the low feed rate is at its “lowest”
setting. (approx. 0.9 pounds per hour)
•
When the “1” light is illuminated on the bar graph the low feed rate is at its “normal” setting.
•
When the “1” & “4” lights are illuminated on the bar graph the low feed rate is at its “highest”
setting.
NOTE: When the stove is set on “1” the “reset trim” values will be shown on the Feed Rate Advance bar
graph. For example if the Reset Trim is set to its lowest setting every time the stove is set to low the “1”
and “3” lights will be illuminated on the bar graph.
e.
HEAT LEVEL ADVANCE
•
This button when pushed will set the pellet feed rate, hence the heat output of your stove. The
levels of heat output will incrementally change on the bar graph starting from level “1” to “4”.
NOTE: When dropping more than 2 heat level settings (i.e. 4 to 1) push the ‘High Fan’ button and allow
the room air fan to run at that setting for at least 5 minutes to prevent the stove from tripping the high
temp thermodisk. If the high temp thermodisk does trip see “SAFETY FEATURES”.
CAUTION: THE “4” SETTING IS DESIGNED FOR TEMPORARY USE ONLY. IF USED FOR
EXTENDED PERIODS, IT CAN SHORTEN THE LIFE EXPECTANCY OF THE UNITS COMPONENTS.
AVOID USE AT THIS SETTING FOR MORE THAN ONE HOUR AT A TIME.
FIGURE 22
OPERATION
14