The more R 600a refrigerant there is in the appliance, the
larger the room in which the appliance is standing needs to
be. In rooms that are too small, a flammable mix of gas and
air may be created if there is a leak. According to the EN
378 standard, every 11 g of R 600a refrigerant requires at
least 1 m
3
space in the room for the appliance. The amount
of refrigerant in your appliance is on the type plate inside the
appliance.
u
Detach the connecting cable from the rear of the appliance,
removing the cable holder at the same time because other-
wise there will be vibratory noise!
After installation:
u
Remove the protective film from the decorative trims.
u
Remove all transit supports.
Fig. 3
u
Swing the transport lock
Fig. 3 (1)
aside and draw it
forwards for removal.
u
Dispose of packaging material (see 4.5) .
Note
u
Clean the appliance (see 6.2) .
If the appliance is installed in a very damp environment,
condensate may form on the outside of the appliance.
u
Always see to good ventilation at the installation site.
4.3 Installation
All the assembly components accompany the appliance.
Fig. 4
Ensure that the following tools are to hand:
q
Cordless screwdriver Torx® 15, 20, 25
q
Spanner 13
q
Screwdriver Torx® 15
q
Flat-blade screwdriver 6
q
Allen key 8
NOTICE
Risk of damage due to condensate!
u
If refrigerator and freezer are installed side-by-side, the
freezer always has to be sited to the right of the refrigerator
(as seen from the front). Condensate is prevented from
forming between the appliances by the foamed-in side wall
heating on the left side of the freezer.
Pay attention that the socket is readily accessible.