Warning, Electrical connection, Appliance dimensions setting up – Liebherr GGPv 6590 ProfiPremiumline User Manual
Page 4

16
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type
plate. The position of the type plate is shown in the section entitled
Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion
of direct current to alternating/three-phase
current) or energy-saving plugs. Risk of dam-
age to the electronic control system!
Appliance dimensions
Setting up
• Avoid positioning the appliance in direct sunlight or near cookers,
radiators and similar sources of heat.
• The floor on which the appliance stands should be
horizontal and level. Compensate for uneven floors
with the adjustable feet.
To alter the height, rotate the bottom
section of the respective adjustable foot.
WARNING!
The height of the foot can be adjusted from 120 mm
to 170 mm.
Do not set the adjustable foot to a
height greater than 170 mm! The
bottom section of the adjustable
foot can become loose and the ap-
pliance may then tip over.
This can lead to serious or even fatal injuries.
• Standard EN 378 specifies that the room in which you install
your appliance must have a volume of 1 m
3
per 8 g of R 290a
refrigerant used in the appliance, so as to avoid the formation of
inflammable gas/air mixtures in the room where the appliance is
located in the event of a leak in the refrigerant circuit. The quantity
of refrigerant used in your appliance is indicated on the type plate
on the inside of the appliance.
• There must be a gap of at least 30 cm
between the upper edge of the appliance
and the ceiling.
Do not cover ventilation open-
ings or grille.
Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the
type plate.
The position of the type plate is shown in
the section entitled Description of the appliance.
Climate rating
Room temperature
4 (SN)
+10°C to +32°C
4 (N)
+16°C to +32°C
4+ (ST)
+16°C to +38°C
4+ (SN-ST)
+10°C to +38°C
5 (T)
+16°C to +43°C
5 (SN-T)
+10°C to +43°C
Do not operate the appliance outside the
specified room temperature range.
Range of appliance use
The appliance is suited only for cooling food.
The appliance is not suited for storing and cooling pharmaceuti-
cals, blood plasma, laboratory preparations or similar substances
and products subject to the Medical Devices Directive 2007/47/EC.
Any misuse of the appliance may result in damage to or spoilage
of the stored goods.
Furthermore, the appliance is unsuited for use in areas exposed
to an explosion hazard.