16 display mode setup screen, 17 time/date setup screen -23 – Bacharach Portable Combustion Analyzer 24-9351 User Manual
Page 38

PCA
Instruction 24-9351
4-22
Operation
4.16 Display Mode Setup Screen
(For PCA Models 30, 35, 60 & 65)
SETUP
DISPLAY
«CO NX
CU NU
The Display Setup Screen is displayed by repeatedly pressing the
MENU
key from the Combustion Test Screen. Use this screen to select whether
the Combustion Test Screen will display the measured values of Carbon
Monoxide and Nitric Oxide (CO and NX), or the calculated values of these
gases (CU and NU) referenced to 0% Oxygen.
To setup the display, first use the
st
keys to move the cursor (
z
) in front
of either
CO NX (measured values), or CU NU (calculated values), and
then press the
key.
Front Panel Key Functions:
– Move cursor (
z
) up
– Move cursor (
z
) down
– Select Display Mode
– Go to Combustion Test Screen
– Go to Time/Date Setup Screen