6troubleshooting – Bosch PROTANKLESS GWH 345/450 ESR User Manual
Page 32
![background image](/manuals/51143/32/background.png)
6 720 607 909
32
Troubleshooting
6
Troubleshooting
Fault Indication
Possible Cause
Check
E9
Shut down by the temperature limiter
(over temperature).
• 1. Check position of heating NTC
• 2. Check temperature limiter, cables
• 3. Check system with air, air vent
• 4. Bleed air from system.
EA
No Flame detected (no ignition).
• 1. Check gas inlet pressure, gas
type, air inside gas pipe
• 2. Check flame, ignition
• 3. Check burner pressure, injectors
• 4. Check ionisation sensor, cable
• 5. Check electronic unit
1)
.
F7
"false flame" (error during self check of
electronic).
• 1. Check for moisture on the
Electronics
• 2. Check cables, sensor contacts
(corrosion)
• 3. Check flame inside Burner
chamber
• 4. Check electronic unit
1)
.
E0
Shut down because of low voltage.
• 1. Check power supply
• 2. Check electronic unit
1)
.
F0
Internal error in the electronic unit.
• 1. Check electronic unit connections
and wiring.
•
2. Replace electronic unit
.
C4
Fan not working
• 1. No power to fan, check for 115
volts at fan
• 2. Check wire connections
.
C6
Shut down by pressure switch.
• 1. Blocked vent
• 2. Fresh air supply inadequate
• 3. Silicone tubes from pressure
switch not connected - clear or clear
and black
• 4. Check wire and connection.
E2
Heating - NTC defect (no function)
• 1. Check heating - NTC
• 2. Check cable (opened, short)
• 3. Check electronic unit
1)
.
A7
Domestic hot water - Tank NTC defect
(no function)
• 1. Check domestic hot water - NTC
• 2. Check cable (opened, short)
• 3. Check electronic unit
1)
.
AA
Flow reduced
• 1. Check heat exchanger - flush or
descale if necessary
.
LED or LCD of the appliance doesn't
start up, no function.
No voltage supply, fuse blown,
transformer etc. defect
• 1. Check voltage supply
• 2. Check fuse
• 3. Check electronic unit
1)
.
Noise; boiling noise (over heating), no
correct function.
Low circulation, air inside installation,
bad heat transfer.
• 1. Check air in system, air vent
• 2. Check heating circulation
• 3. Check heat exchanger
• 4. Check gas type, injectors, gas
valve.
Table 16