beautypg.com

Bosch PROTANKLESS GWH 345/450 ESR User Manual

Page 16

background image

6 720 607 909

16

Installation instructions

Selecting inlet air restrictor

Note: Before installing the combustion air inlet
accessory, the appropriate inlet air restrictor must
be determined using Tables 6, 7 and 8.
Refer to Fig. 15 for mounting sequence.

B Determine the total length of the straight sections of

3" stainless steel exhaust and enter that length in line
1.

B Count the number of 90° elbows used and enter that

value in line 2.

B Count the number of 45° elbows used and enter that

value in line 3.

B For model GWH 345 ESR, enter a 1 in line 4 for

model GWH 450 ESR enter a 1 in line 5.

B Repeat steps 1 through 4 for the 3" intake pipe and

enter those values in the intake section.

B Add the totals from the Exhaust table and the Intake

table to determine the equivalent vent length. Use
this value in Table 6 to determine which restrictor
size to use.

Example

Exhaust

• 10 - 3' straight sections

• 1 - 1' straight section

Total length 31'

• 1 - 90° elbow

• 1 - GWH 450 ESR termination.

Intake

• 5 - 4' straight sections

• 2 - 1' straight sections

Total length 22'

• 2 - 90° elbows

• 1 - GWH 450 ESR termination.

Example

Using table 8, the following restrictors would be
required:

• GWH 450 ESR NG - restrictor 55

• GWH 450 ESR LP - restrictor 55.

Exhaust

1

Straight section length

__ x 1 =

____

2

90° elbows (qty)

__ x 6 =

____

3

45° elbows (qty)

__ x 3 =

____

4

GWH 345 ESR termination

__ x 15 =

____

5

GWH 450 ESR termination

__ x 12 =

____

6

Total:

____

Intake

1

Straight section length

__ x .5 =

____

2

90° elbows (qty)

__ x 3 =

____

3

45° elbows (qty)

__ x 1.5

____

4

GWH 345 ESR termination

__ x 6 =

____

5

GWH 450 ESR termination

__ x 3 =

____

6

Total:

____

7

Total equivalent vent length =

____

Table 6 Determining equivalent vent length (see

example in Table 7)

Exhaust

Straight section length

21

x 1 =

21

90° elbows (qty)

1 x 6 =

6

45° elbows (qty)

0 x 3 =

0

GWH 345 ESR termination

0 x 15 =

0

GWH 450 ESR termination

1 x 12 =

12

Total:

39

Intake

Straight section length

22 x .5 =

11

90° elbows (qty)

2 x 3 =

6

45° elbows (qty)

0 x 1.5 =

0

GWH 345 ESR termination

0 x 6 =

0

GWH 450 ESR termination

1 x 3 =

3

Total:

20

Total equivalent vent length =

59