M
aintenance and care
Replace drive belt
1. Unplug the vacuum from electrical outlet.
2. With rotating floor brush removed from
vacuum cleaner (Steps 1-4 of check
rotating floor brush and drive belt), grasp
old drive belt and remove from motor
pulley. Discard the old drive belt.
3 Place new drive belt over motor pulley
and loop other end over rotating floor
brush in the space between the bristles.
notE: It is important that you use
only genuine BISSELL replacement
belts. generic belts may not meet
the exacting specifications required
to keep your vacuum operating at
its peak performance. the use of
unbranded belts could lead to early
failure of the vacuum and could void
your warranty.
4. Pull the rotating floor brush firmly into
position, stretching the drive belt, and
place ends of rotating floor brush
down into the slots on sides as shown.
Alignment of brush ends in slots may be
necessary to fully insert the brush.
5. Turn rotating floor brush by hand several
times in the direction of motor pulley. If
properly installed, drive belt will center
itself on rotating brush crown.
6. Insert front edge of brush cover, rotate into
place, and snap 3 latches.
Motor Pulley
3.
2.
4.