SERVICE TOOLS (cont.)

PROGRAMMING THE BREWER (cont.)

the next function screen. Press YES to run tests

on various components and outputs within the

brewer.

5. The display should read TEST OUTPUTS?.

6. In TEST OUTPUTS screen, press NO. Continue to

press and release NO until the display reads TEST

FREQUENCY?.

7. Press and release YES. The display will show the

frequency of the sensor coil circuits. This is for

diagnostic service use when troubleshooting this

circuit.

8. After the coils have been tested, press and release

the ON/OFF switch (either on DUAL brewers)

located on the front switch panel. This will exit

the TEST FREQUENCY function and return to the

MAIN SCREEN.

NOTE: If the operator wishes to test more than one

function in the SERVICE TOOLS section (outputs,

switches, servers, or coil frequency), it is not

necessary to exit the program. Use the flow chart

for SERVICE TOOLS to navigate to a particular

function.

FACTORY DEFAULTS

This function allows the operator to erase all of the

previously entered recipes and ad messages. Factory-

set default values will replace all previous settings.

EXIT

EXIT

REPLACE

WILL REPLACE ALL

BREW SETTINGS

ARE YOU SURE?

NO YES

FACTORY DEFAULTS

NO YES

ThermoF SoftHeat

DONE

SEL BREWER TYPE?

NO YES

P2312

Procedure to set factory defaults:

1. Press and hold the upper right hidden switch until

UNITS appears. Release the switch. Press and

release the upper right hidden switch until the

display reads SEL BREWER TYPE?.

2. Pressing NO in this screen will advance to FACTORY

DEFAULTS. Press and release YES. The display

should read ThermoF SoftHeat. The selected

brewer type will be flashing. When correct brewer

type is selected press DONE.

3. The display should now read FACTORY DEFAULTS.

Pressing NO in this screen will revert to the MAIN

SCREEN. Press YES to replace the defaults. This

advances to WILL REPLACE ALL BREWING SET-

TINGS. This screen will alternate with ARE YOU

SURE?.

4. Pressing NO in the confirmation screen will revert

to MAIN SCREEN, without resetting the brewing

setups to the defaults. Press YES to load the de-

faults. This will then revert to the MAIN SCREEN,

and the factory default values will replace all

previously entered values. It will NOT reset the

summation Brew counter.