PROGRAMMING THE BREWER (cont.)

SERVICE TOOLS (cont.)
NOTE:
To bypass testing any component, press NEXT

to advance to the next one, without testing the previ-

ous component.

10. To test LEFT BYPASS, press ON. If the bypass

valve is functional, water should run from the left

brew bypass.

11. Press OFF to end flow of water.

12. Press NEXT to advance to the next component to

be tested.

13. To test LEFT FUNNEL LOCK, press ON. If the fun-

nel lock is functional, the lock will come down to

hold the funnel in place.

14. Press OFF to retract the funnel lock.

15. Press NEXT to advance to the next component to

be tested.

16. Follow steps 7 through 15 to test the right side

components.

17. To test REFILL VALVE, press ON. If the refill valve

is functional, the sound of the valve operating will

be heard.

18. Press OFF to end testing of refill valve.

19. Press NEXT to advance to the next component to

be tested.

20. To test TANK HEATERS, connect a voltmeter across

each of the tank heaters to check for voltage.

21. Press ON. The correct voltage should be present

at the heater terminals.

22. Press OFF to end testing of the tank heaters.

NOTE: The tank heater will automatically turn off if

left on too long.

23. After testing the tank heater, press NEXT to advance

to the next test.

24. The HEATER CONTACTOR is used only on certain

models. Check the machine schematic to see if the

contactor is present. Connect a voltmeter across a

tank heater that is operated by the contactor and

press ON to check that correct voltage is present.

Press OFF and confirm the voltage is zero.

25. Press NEXT to return to TEST OUTPUTS.

26. o exit SERVICE TOOLS, press and release the ON/

OFF switch (either on DUAL brewers) located on

the front switch panel. This will return to the MAIN

SCREEN.

Procedure to test switches:

This function allows the operator to test the opera-

tion of the individual switches on the front panel.

1. Place brew funnel(s) into rails on the brewer (both

sides on DUAL brewers).

2. Place a server beneath each brew funnel.

3. Press and hold the upper right hidden switch until

display reads UNITS. Release the switch. Continue

to press and release switch until SERVICE TOOLS

appears.

4. Press YES to run tests on various components

and outputs within the brewer. (Pressing NO will

exit this function and advance to the next function

screen.)

5. The display should read TEST OUTPUTS.

6. In TEST OUTPUTS screen, press NO. This advances

to TEST SWITCHES.

7. Pressing NO in this screen will advance to the

next function. Press YES in the TEST SWITCHES

screen to test the switches. The display will read

NOTHING PRESSED.

8. From this screen, press any of the switches on the

front of the brewer except the upper right hidden

switch. While the switch is pressed, the display

shows the name of that switch. If the name does

not appear, or if it remains after the switch has been

released, the switch is defective. Each switch can

be tested in this manner.

9. After all switches have been tested, press and re-

lease the right hidden switch (®). This will return

to TEST SWITCHES?. Press and release switch

again to advance to TEST SERVERS?. Another

alternative is to press and release the ON/OFF

switch (either on DUAL brewers) located on the

front switch panel. This will exit TEST SWITCHES

and return to the MAIN SCREEN.

Procedures to test coil frequency:

1. Place brew funnel(s) into funnel rails of the brewer

(both side on DUAL brewers).

2. Place a ThermoFresh server beneath brew

funnel(s).

3. Press and hold the upper right hidden switch

until the display reads UNITS. Release the switch.

Continue pressing and releasing the upper right

hidden switch until SERVICE TOOLS appears.

4. Pressing NO will exit this function and advance to

41342 080108