PROGRAMMING THE BREWER (cont.)

REFILL - Range: 20 to 230

This function allows the operator to adjust the

sensitivity of the refill circuit. This is mainly a trouble-

shooting feature. Water in different geographical loca-

tions can have different conductivities. By adjusting

the sensitivity of the refill circuit, this will allow the

brewer to operate under various water conditions.

Procedure to set the sensitivity threshold of the

refill circuit:

NOTE: Make sure the water in the tank is touching

the refill probe.

1. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Continue to

press and release switch until the display reads

REFILL and shows a number on both sides of the

word.

2. To adjust the threshold setting, press (-) to de-

crease, or (+) to increase the setting.

NOTE: Always make sure that the number on the right

is larger than the number on the left when water is in

contact with the refill probe in the tank.

3. When finished, press and release DONE. This saves

the new setting and advances to the next function

screen:

SPRY OZ/M (SINGLE brewers)

L SPRY OZ/M (DUAL brewers). Another alternative

is to press and release the ON/OFF switch (either on

DUAL brewers) located on the front switch panel

to exit REFILL and return to the MAIN SCREEN.

Procedure to set ready temperature:

1. Press and hold upper right hidden switch until the

display reads UNITS. Release switch. Continue to

press and release switch until the display reads

SET READY.

2. To adjust the ready temperature, press the (-)

button to decrease, or (+) to increase the ready

temperature.

3. When finished, press and release DONE to save

the new setting, exit the SET READY function and

advance to the next function screen, REFILL.

Another alternative is to press and release the

ON/OFF switch (either on DUAL brewers) located

on the front switch panel to exit the SET READY

function and return to the MAIN SCREEN.

2. To adjust the brew temperature, press (-) to de-

crease or (+) to increase the brew temperature.

3. When finished, press and release DONE to save

the new setting, exit the SET TEMP function and

advance to the next function screen, SET READY.

Another alternative is to press and release the ON/

OFF switch (either on DUAL brewers) located on

the front switch panel to exit the SET TEMP func-

tion and return to the MAIN SCREEN.

SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)

This function allows the operator to set the mini-

mum temperature allowable to start a brew cycle. The

range can be from 185˚F (85˚C) to within 2˚F (-1.7°C)

of the SET TEMP. The water must be at the SET READY

temperature or higher for the display to indicate READY

TO BREW. If brew lockout is enabled, the brewing pro-

cess will not start below this READY temperature.

NOTE: The upper limit for SET READY temperature

is 2˚F (-1.7°C) less than the water temperature (SET

TEMP) setting.

SET READY: XXX°

(-)

DONE

(+)

XXX REFILL -> XXX

(-)

DONE

(+)

SET TEMP (cont.)

41342 080108