Warning, Roubleshooting, No power at rotating floor brush – Bissell 3750 SERIES-220-240V EN User Manual
Page 16

16
w w w . b i s s e l l . c o m
T
roubleshooting
Vacuum cleaner won't run.
possible causes
Remedies
1. Power cord not firmly plugged in
1. Check electrical plug
2. Thermal protector activated
2. Allow cleaner to cool for 30 minutes,
see pg. 15
no power at rotating floor brush.
possible causes
Remedies
1. Cylinder is not securely seated
1. Remove cylinder and replace, making sure
that it “clicks” into place
2. Brush switch turned to off
(O)
2. Make sure brush switch is in on
(I)
position
3. Vacuum is in upright position
3. Recline vacuum to operate brush
Vacuum cleaner or tools won't pick up dirt.
possible causes
Remedies
1. Incorrect height adjustment
1. Adjust powerfoot to correct height setting
2. Hose not attached to suction opening
2. Grasp hose grip and firmly push onto the base
3. Crack or hole in hose
3. Check hose and replace if needed
4. Drive belt broken, worn or off motor pulley
4. Reposition or replace drive belt, see pg. 12
5. Rotating floor brush bristles worn
5. Replace brush
6. Rotating floor brush jammed
6. Remove brush and clean debris from
brush ends
7. Clog in vacuum
7. Follow instructions on pg. 14 for clearing clogs
8. Dirt container full
8. Empty dirt container
9. Dirt container or upper tank not installed properly
9. Position correctly and lock in place
10. Filters are dirty
10. Check and clean or replace upper tank,
pre-motor and post-motor filters
WaRnInG:
to reduce the risk of injury from moving
parts and/ or electrical shock, turn power
switch off and disconnect plug from
electrical outlet before performing
troubleshooting checks.