Model number nomenclature ari* capacities, 702b with icm fiop ratings, Cooling capacities and efficiencies – Bryant 702B User Manual
Page 3

—3—
Model number nomenclature
ARI* capacities
COOLING CAPACITIES AND EFFICIENCIES
702B WITH ICM FIOP RATINGS
**“A” Capacity- 80°F indoor db/67°F indoor wb & 95°F outdoor db.
702B
N
X
024
Model Number
702B
– Single
Packaged Electric
Cooling
Electrical Supply
N
– *208/230-1-60
P
– 208/230-3-60
E
– 460-3-60
Nominal Cooling Capacity
024
– 2 ton
030
– 2.5 ton
036
– 3 ton
042
– 3.5 ton
048
– 4 ton
060
– 5 ton
UNIT
702B
NOMINAL
TONS
STANDARD
CFM
NET COOLING
CAPACITIES
(Btuh)
SEER†
SOUND
RATINGS‡
(dB)
024
2
800
24,000
12.0
72
030
2-1/2
1000
29,000
12.0
72
036
3
1200
35,000
12.0
72
042
3-1/2
1400
41,000
12.0
73
048
4
1600
48,000
12.0
78
060
5
1750
59,000
12.0
76
UNIT
702B
“A”**
CAPACITY
“A”**
EER
SEER
024
24,000
10.7
12.7
030
29,000
10.7
12.7
036
35,000
10.6
12.5
042
41,000
10.7
12.5
048
48,000
10.5
12.3
060
59,000
10.4
12.3
LEGEND
dB
— Sound Levels (decibels)
db
— Dry Bulb
SEER
— Seasonal Energy Efficiency Ratio
wb
— Wet Bulb
* Air Conditioning & Refrigeration Institute.
† Rated in accordance with U.S. Government DOE Department of
Energy) test procedures and/or ARI Standard 210/240-94.
‡ Tested in accordance with ARI Standard 270-95 (not listed in ARI).
NOTES:
1. Ratings are net values, reflecting the effects of circulating fan heat.
Ratings are based on:
Cooling Standard: 80°F db, 67°F wb indoor entering-air tempera-
ture and 95°F db outdoor entering-air temperature.
2. Before purchasing this appliance, read important energy cost and
efficiency information available from your retailer.
TT
AL
— Aluminum
CU
— Copper
000
VS
Options
(None)
– Wire Grille
AD
– Louvered Grille
BT
– Wire Grille and Vinyl-Coated Condenser
Coil Fin
XT
– Louvered Grille and Vinyl-Coated Con-
denser Coil Fin
CC
– Wire Grille, AL Evaporator and CU/CU
Condenser Coil
AC
– Louvered Grille, AL Evaporator and CU/
CU con
Options
BT
– AL evap, vinyl condens
CC
– AL evap, CU condens
CU
– CU evap & condens
VS
– Variable speed (VS) Unit
VT
– VS, AL evap, vinyl condens
VC
– VS, AL evap, CU condens
VU
– VS, CU evap & condens
Only used if ordering an option
*Variable speed units are only available
in 208/230-1-60 (N)