beautypg.com

Steps for starting your furnace – Bryant 311AAV User Manual

Page 4

background image

4

STEPS FOR STARTING
YOUR FURNACE

1. Set your room thermostat to the

lowest temperature setting. (See
Fig. 5.)

2. Close the external manual gas

valve. (See Fig. 6.)

3. Turn OFF the electrical supply to

your furnace. (See Fig. 7.)

6

7

8

4. Remove the outer door by remov-

ing two screws. (See Fig. 8.)

5. The gas valve will have a control

switch to turn off and on. Turn the
control switch on the gas valve to
the OFF position and wait 5 min-
utes. (See Fig. 9.)

6. After waiting 5 minutes, turn the

control switch on the gas valve to
the ON position. (See Fig. 10.)

7. Replace the outer door using two

screws. (See Fig. 11.)

8. Turn ON the electrical supply to

the furnace. (See Fig. 12.)

9. Open the external manual gas

valve. (See Fig. 13.)

10. Set the room thermostat to a tem-

perature slightly above the room
temperature. This will automati-
cally signal the furnace to start. The
inducer motor will start, and the hot
surface igniter will energize. When
hot, the igniter will have an orange
glow.

9

10

CL

O

S

E