TROUBLESHOOTING (cont.)

PROBLEM

Brew cycle will not start (cont)

Brew cycle starts with brew lockout
relay engaged.

PROBABLE CAUSE

2. No power or incorrect voltage to
the brewer (cont)

3. Water level below pump housing.
(Water level in the hot water gauge
glass should be approximately half
full).

4. ON/OFF Switch

5. Start Switch

6. Relay

7. Timer

8. Pump

9. Solenoid Valve

10. Strainer

1. Relay

REMEDY

(A4) Check the terminal block for
440 volts ac across the black and
blue terminals, black and red termi-
nals and the red and blue terminals
on four wire three phase 440 volt
models.

(B) Check circuit breakers or fuses.

Be sure water shut-off valve is open
and that the in-line filters or strain-
ers are not blocking water flow. (Do
not confuse water shut-off valve with
the manual fill and drain valve un-
derneath the brewer).

Refer to

Service

- ON/OFF Switch for

testing. See page 22

Refer to

Service

- Start Switches for

testing procedures. See page 29

Refer to

Service

- Relay for testing

procedures. See page 24

Refer to

Service

- Timer for testing

procedures. See page 31 or 33

Refer to

Service

- Pump for testing

procedures. See page 23

Refer to

Service

- Solenoid Valve for

testing procedures. See page 27

(A) Direction of flow arrow must be
pointing towards brewer.

(B) Remove the strainer and check
for obstructions. Clear or replace.

Refer to

Service

- Relay for testing

procedures. See page 24