beautypg.com

Bunn U3 U3A User Manual

Page 10

background image

Page 10

TROUBLESHOOTING (cont.)

PROBLEM

Tank not filling

Water running out of the overflow

PROBABLE CAUSE

1.ON/OFF Switch (This switch
must be in the "ON" position for the
refill circuit to operate.

2. No water

3. Solenoid Valve

4. Probe

5. Liquid Level Board

1.Brewer not level

2. Solenoid Valve

3. Liquid Level Board

4. Probe

5. Manual fill and drain valve un-
derneath brewer open.

REMEDY

Refer to

Service

- ON/OFF Switch

for testing procedures. See page
22

Be sure water shut-off is open and
that in-line filters or strainers are
not blocking water flow. (Do not
confuse water shut-off valve with
the manual fill and drain valve un-
derneath brewer).

Refer to

Service

- Solenoid Valve

for testing procedures. See page
27

Refer to

Service

- Probe for testing

procedures. See page 20

Refer to

Service

- Liquid Level

Board for testing procedures. See
page 20

Brewer must be level and installed
on a sturdy structure.

Refer to

Service

- Solenoid Valve

for testing procedures. See page
27

Refer to

Service

-Liquid Level

Board for testing procedures. See
page 20

Refer to

Service

- Probe for test-

ing procedures. See page 20

Be sure valve is closed.

10060 080900