beautypg.com

Bunn U3 U3A User Manual

Page 11

background image

Page 11

PROBABLE CAUSE

1. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
Bunn-O-Matic replacement part
#29329.1000

2. Control Thermostat

3. Tank Heater(s)

4. Contactor

1. Circuit Breaker

2. Tank Heater(s)

1. Timer

2. Start Switch

1. Timer

2. Solenoid Valve

3. Lime build-up in swing spout
and pump tubing.

1. Filters

2. Hole in bottom of funnel ob-
structed.

TROUBLESHOOTING (cont.)

PROBLEM

Water not hot

Circuit breaker keeps tripping

Water keeps running from swing
spout

Inconsistent coffee yield

Funnels overflow

REMEDY

Refer to

Service

- Limit Thermo-

stat for testing procedures. See
page19

Refer to

Service

- Control Ther-

mostat for testing procedures. See
page 17

Refer to

Service

- Tank Heater for

testing procedures. See page 30

Refer to

Service

- Contactor for

testing procedures. See page 15

Refer to

Service -

Circuit Breaker

for testing procedures. See page
14

Refer to

Service

- Tank Heater for

testing procedures. See page 30

Refer to

Service -

Timer for testing

procedures. See page 31 or 33

Refer to

Service -

Start Switch for

testing procedures. See page 29

Refer to

Service -

Timer for testing

procedures. See page 31 or 33

Refer to

Service -

Solenoid Valve

for testing procedures. See page
27

Remove swing spout and insert
deliming rod down into pump tub-
ing as far as possible.

Use Bunn

®

filters made for the U3

brewer.

Remove obstruction.

10060 080900