Bunn U3 U3A User Manual

Page 12

background image

Page 12

TROUBLESHOOTING (cont.)

PROBLEM

Funnels overflow (cont.)

Coffee reservoir overflows

Brewer is making unusal noises

PROBABLE CAUSE

REMEDY

3. Pump - Flow Rate

4. Soft Water

1. Coffee reservoir not completely
empty befor a brew cycle was
started.

2. Timer

3. Pump - Flow Rate

1. Solenoid Valve

2. Plumbing lines

3. Water supply

4. Tank Heater(s)

Check pump flow rate with a watch.
Pump flow rate should be approxi-
mately 24 ounces in 15 seconds.
Be sure pump assembly is free of
any obstructions.

When using a water softener, a
coarse grind of coffee may be pre-
ferred. If required, a bypass sys-
tem is available as an optional
feature.

Be sure coffee reservoir is empty
before brew cycle is started.

Refer to

Service

-Timer for test-

ing procedures. See page 31 or 33

Check pump flow rate with a watch.
Pump flow rate should be approxi-
mately 24 ounces in 15 seconds.
Be sure pump assembly is free of
any obstructions.

The nut on the solenoid must be
tight or it will vibrate during opera-
tion.

Plumbing lines should not be rest-
ing on the counter top.

(A) The brewer must be connected
to a cold water line.

(B) Water pressure to the brewer
must not exceed 90 psi (620 kPa).
Install a regulator if necessary to
lower the pressure to approxi-
mately 50 psi (345 kPa).

Remove and clean lime off the
tank heater. See page 30

10060 080900