beautypg.com

Bunn U3 U3A User Manual

Page 20

background image

Page 20

8. Disconnect the brewer from the power source and

remove the jumper wire from terminal 4.

If voltage is present as described, liquid level board is
operating properly, proceed to #9.
If voltage is not present as described, replace the liquid
level board.