Bryant Deluxe 4-Way Multipoise Variable-Capacity Direct-Vent Condensing Gas Furnace A93040 User Manual
Page 5
10. Remove screws attaching burner box to cell panel. (See Fig.
5.)
NOTE:
Burner box, cover, manifold, gas valve, and burner
assembly should be removed as 1 assembly.
11. Clean heat exchanger openings with a vacuum and a soft
brush. (See Fig. 6.)
NOTE:
After cleaning, inspect the heat exchangers to ensure they
are free of all foreign objects that may restrict flow of combustion
products.
12. Reverse items 4 through 10 for reassembly.
WARNING:
The ground wire from the gas valve MUST
be attached to the burner box attachment screw. Failure to
attach this ground wire to an adequate casing ground will
cause the furnace control to lock out.
NOTE:
Be sure burner box gasket is installed between burner box
and cell panel. If gasket is damaged, replace it.
NOTE:
Inspect combustion-air intake housing. If foamed gasket
was removed, check for any damage. If gasket is damaged in any
way, it must be repaired. To repair, remove damaged gasket
section, apply sealant releasing agent such as PAM cooking spray
or equivalent (must not contain corn or canola oil, aromatic or
halogenated hydrocarbons or inadequate seal may occur) to burner