11. INSTALL THE DEVIATOR (INTERIOR BLOWER)

Install the deviator as shown.

NOTE: To prevent the deviator from sliding out of the rough-in plate, put

some tape on the deviator base after sliding it into the rough-in
plate (provided with the P5 and P8 blower) opening. If installed
correctly, the deviator will protrude about 1/8” above the rough-in
plate.

HD0087

12. INSTALL THE ADAPTER (INTERIOR BLOWER)

Using two (2) no. 6 x 1/2’’ screws provided with insert, secure the adapter to the top of the rough-in plate. Remove tape
from damper flap. Seal the adapter to the rough-in plate by using duct tape.

HD0005

HD0006

10. REMOVE THE KNOCK-OUT OPENING (INTERIOR BLOWER)

Remove the knockout on rough-in plate. See picture below.

CAUTION

When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the
knockout corresponding to the ducting installed (10’’ or 14’’ adapter/damper).

Removing vertical knockout opening on rough-in plate

HD0077

14’’

KNOCK

OUT

10’’

KNOCK

OUT