READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION

REFER TO EXPLODED VIEWS FOR COMPONENT NAMES/
NUMBERS


Unpack the unit. Inspect all components for completeness and
condition. Ensure that all packing materials have been removed
from the unit.


Verify that the Spray Head Gasket and Spray Disk are properly
installed.


LEVELING THE UNIT


Verify that provided adjustable legs are installed at each corner of
the brewer.


Set Brewer in its operating location. Level the Brewer. A spirit
level should be placed on the top of the unit, at the edge, as a
guide when making level adjustments.


Level the unit from left to right and front to back by turning the
adjustable feet. Be sure all four feet touch the counter to prevent
tipping.

PLUMBER’S INSTALLATION INSTRUCTIONS


Brewer should be connected to a POTABLE WATER, COLD
WATER
line. Flush water line before connecting to Brewer.


DO NOT use a saddle valve with a self-piercing tap for the water
line connection. Such a tap can become restricted by waterline
debris. For systems that must use a saddle tap, shut off the main
water supply and drill a 3/16” (minimum) tap for the saddle
connection, in order to insure an ample water supply. Remember
to flush the line prior to installing the saddle.


The brewer must be installed on a water line with average
pressure between 20 PSI and 90 PSI. If your water pressure
exceeds 90 PSI at anytime, a pressure regulator must be
installed in the water supply line to limit the pressure to not more
than 90 PSI in order to avoid damage to lines and solenoid.


IMPORTANT:
To enable the installer to make
a quality installation and to
minimize installation time, the
following suggestions and tests
should be done before the
actual unit installation is started:

CAUTION:

ELECTRICAL
DAMAGE


DO NOT plug in or energize this
appliance until all Installation
Instructions are read and
followed. Damage to the
Brewer will occur if these
instructions are not followed.

CAUTION:

UNSTABLE
EQUIPMENT HAZARD


DO NOT operate brewer unless
factory supplied adjustable legs
are installed and properly
adjusted.
It is very important for safety
and for proper operation that the
brewer is level and stable when
standing in its final operating
position. Provided adjustable
legs must be installed at each
corner of the unit. Failure to
do so will result in movement of
the brewer which can cause
personal Injury and/or damage
to brewer.


NOTE: Water supply inlet line
must meet certain minimum
criteria to insure successful
operation of the brewer.
Bloomfield recommends 1/4"
copper tubing for installation of
less than 12 feet and 3/8" for
more than 12 feet from a 1/2"
water supply line.