SERVICING INSTRUCTIONS (continued)

TEMPERATURE ADJUSTMENT

Unplug power cord or turn circuit breaker OFF. Remove top
panel.
Pull vent tube out of tank lid and insert a thermometer of known
accuracy in hole. Reconnect brewer to electrical power.
Place empty container under brew chamber. Energize brewer
and allow unit to heat. When READY TO BREW light glows,
read the temperature displayed on thermometer.


Adjust WATER TEMP by turning shaft of thermostat; clockwise
increases temperature. Refer to Table 1 below for proper
brewing temperature based on altitude.

Upon completion, remove thermometer and reinstall the plug.

Fig. 10 Checking and Adjusting Brew Temperature

CAUTION:

SHOCK HAZARD

These procedures involve
exposed electrical circuits.
These procedures are to be
performed by qualified
technical personnel only.


NOTE:
Optimum brewing temperature
range is 195ºF to 205ºF (90ºC
to 96ºC).

IMPORTANT:
A mechanical thermostat will
maintain temperature within
±5ºF. To prevent boiling water
in the brewer, thermostat should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 5ºF.

Table 1 Boiling Temperature by Altitude

12

ELEVATION (feet above seal level)

0

50

0

1,0

00

1,

50

0

2,

00

0

2,50

0

3,00

0

3,50

0

4,00

0

4,5

00

5,

00

0

5,5

00

6,0

00

6,

50

0

TEM

P

. (ºF

)

195

200

205

210

190

IDEAL
BREWING
TEMPERATURE

MAXIMUM
TEMPERATURE
SETTING

BOILING
POINT OF
WATER

ELEVATION (meters above seal level)

0

15

0

300

450 600 75

0

90

0

1.0

50

1.2

00

1.35

0

1.5

00

1.6

50

1.

80

0

1.

95

0

TEM

P

. (ºC

)

91

94

97

100

88

IDEAL
BREWING
TEMPERATURE
RANGE

MAXIMUM
TEMPERATURE
SETTING

BOILING
POINT OF
WATER

605

70

988

Ow

ners

M

a

nual

Integri

ty

5

W
D

e

can

te

r B
rew
er