Servicing instructions caution – Bloomfield 8752 User Manual
Page 13

SERVICING INSTRUCTIONS
CAUTION:
SHOCK HAZARD 
 
Opening access panels or 
removing warmer plates on this 
brew may expose uninsulated 
electrical components. 
Disconnect brewer from 
electrical power before 
removing any panel. 
ACCESS PANELS 
 
TOP PANEL: 
Remove top panel to access hot water tank, thermostat, heating 
elements, brew circuit tubing and faucet tubing. 
Top panel is held by two screws at the front and a retaining lip at 
the rear. 
 
FRONT PANELS: 
Remove upper front panel to access timer and hi-limit. Remove 
button plugs for simple adjustments or reset. 
Upper front panel is held by two screws at the bottom and a 
retaining lip at the top. 
 
SOLENOID DOOR: 
Remove solenoid door to access solenoid and tubing 
connections. 
Solenoid door is held by two screws and a retaining lip. 
 
TERMINAL BLOCK ACCESS: 
Remove door to access wiring connections 
Access door is held by two screws and a retaining lip. 
 
WARMER PLATES: 
Warmer plates unscrew counterclockwise to access warmer 
elements and electrical connections. 
Fig. 9 Access Panels
11
605 7098
8
O
w
n
e
rs
M
anua
l
Int
e
gri
ty 5
W
Decan
ter Brew
er