Servicing instructions caution – Bloomfield 8752 User Manual
Page 13
SERVICING INSTRUCTIONS
CAUTION:
SHOCK HAZARD
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel.
ACCESS PANELS
TOP PANEL:
Remove top panel to access hot water tank, thermostat, heating
elements, brew circuit tubing and faucet tubing.
Top panel is held by two screws at the front and a retaining lip at
the rear.
FRONT PANELS:
Remove upper front panel to access timer and hi-limit. Remove
button plugs for simple adjustments or reset.
Upper front panel is held by two screws at the bottom and a
retaining lip at the top.
SOLENOID DOOR:
Remove solenoid door to access solenoid and tubing
connections.
Solenoid door is held by two screws and a retaining lip.
TERMINAL BLOCK ACCESS:
Remove door to access wiring connections
Access door is held by two screws and a retaining lip.
WARMER PLATES:
Warmer plates unscrew counterclockwise to access warmer
elements and electrical connections.
Fig. 9 Access Panels
11
605 7098
8
O
w
n
e
rs
M
anua
l
Int
e
gri
ty 5
W
Decan
ter Brew
er