beautypg.com

Connections, Speakers – Bogen WV100 User Manual

Page 8

background image

Connections

Speakers

Transformer-Coupled Speaker Connections

Transformer-coupled, constant voltage speaker loads are connected to
their respective load type (i.e., 70V speakers to the 70V terminal, 25V
speaker systems to the 25V terminals) and the COM terminal. Make sure
the selector switch is in the TRANS OUT position. A separate 8-ohm ter-
minal is provided to drive 8-ohm (low-impedance) speakers through an
output transformer tap.
The speaker terminals can accept up to a #10 spade lug and have integral
clamping plates that make wiring easier.

4-Ohm Low-Impedance Speaker Connections

A low-impedance (4

Ω) speaker load can be driven directly without trans-

former coupling by connecting the load to the 4

Ω terminal and the GND

terminal. Make sure the selector switch is in the DIRECT OUT position.
Bypassing the output transformer and driving the speaker load directly
provides the advantage of better bass response. To maximize the power
delivered to the speakers, their combined load impedance should be 4
ohms. Connecting higher load impedances is electrically acceptable, but
the mismatch in load impedance will cause the speaker load to only
receive a portion of the power that the amplifier is capable of delivering.
It is not acceptable to connect low-impedance speakers to the 70V and
25V outputs.

Note jumper link shorting the
GND to the COM terminal.

Typical connections to a low-impedance
(non-transformer-coupled) speaker load

Typical connections to a 70V

transformer-coupled speaker

Note switch is set
to DIRECT OUT

Note switch is set
to TRANS OUT

6

Note jumper link shorting the
GND to the COM terminal.

This manual is related to the following products: