Olympus E-3 User Manual
Page 63

63
EN
Focusing
an
d shooti
ng functio
n
s
4
Bulb shooting with the remote control
Set the shooting mode to [A].
g“Bulb shooting” (P. 44)
You can select the interval from the time the mirror is raised until the shutter is released. This
diminishes camera shake caused by vibrations when the mirror moves. This feature can be
useful in astrophotography and microscope photography or other photographic situations
where a very slow shutter speed is used, and camera vibration needs to be kept to a minimum.
1
MENU
[
X][ANTI-SHOCKz]
2
Select from 1 to 30 seconds for the time after the mirror is raised until the shutter is
released and press the
i button.
3
Anti-shock is added to the shooting functions individually (single-frame shooting,
sequential shooting, self-timer shooting, and remote control shooting). For the
setting method, see “Sequential shooting” (
gP. 59).
You can reduce the amount of camera shake that easily occurs when shooting in low light
situations or shooting with high magnification.
OFF
Image stabilizer is off.
I.S. 1
Image stabilizer is on.
I.S. 2
This is used when panning in the horizontal direction to achieve a blurred background.
The horizontal image stabilizer is turned off, and only the vertical image stabilizer is
activated.
1
Press and release the o button, and then use the dial
to make the setting.
Anti-shock
Image stabilizer
Press the W button on the remote control
to open the shutter.
When the time set in “BULB
TIMER” (
gP. 103) elapses, the shutter
closes automatically.
Press the T button to close the shutter.
o
button
j
k