Water leakage test – Olympus PT-EP08 User Manual
Page 40

EN 15
EN
Water Leakage Test
The final test after loading the camera is explained below. Always perform this test. It can be performed
easily in a water tank or a bathtub. Confirm the operation of the different buttons. The required time is
about five minutes.
• At first, immerse the Case for only three seconds and check that no water enters the Case.
• Next, immerse the Case for 30 seconds and check that no water enters the Case.
• Then, immerse the Case for 3 minutes, operate all buttons and levers, and check the following:
- check that no water drops have the entered the Case.
- check that the Case is not fogged internally.
- check that no water has entered the Case.
• If the inside of the Case becomes fogged or there are water drops in the Case, repeat the maintenance
of the O-ring and perform the water leakage test again.
PT-EP08_EN.Book Page 15 Friday, June 29, 2012 11:02 AM