Hose and cable lengths

LeftĆhand connection

RightĆhand connection

b

d

c

a

e

g

d

f

a = 55.0 in. / 140 cm (approx.)

b = 51.0 in. / 130 cm (approx.)

c = 33.5 in. / 85 cm (approx.)

d = 39.0 in. / 100 cm (max.)

e = 69.0 in. / 175 cm (approx.)

f = 34.6 in. / 88 cm (approx.)

g = 55.0 in. / 140 cm (approx.)

Other hoses

Available from appliance dealers:

-

Extended supply hose

(approx. 96.1 in. /2.44 m).

Water connection

Water supply

CAUTION

The washing machine must only be

operated with cold and hot (max.

140 °F / 60 °C) tap water. Do not

connect the appliance to the mixer

tap of an unpressurized hotĆwater

boiler.

If in doubt, have the water connection

installed by an authorized technician.

The water supply hoses must not be:

-

Bent or flattened.

-

Modified or cut (stability can

no longer be guaranteed).

Plastic threads must only be tightened

by hand. Do not remove the strainers

from the water supply hoses.

Observe the water pressure in the

supply network:

-

The water pressure should be

between 14.5 and 145 p.s.i.

(1 and 10 bars) when the tap

is turned on, at least 2.2 U. S.

gallons (8 liters) of water should be

discharged per minute.

-

A pressure regulator valve must be

installed if the maximum water

pressure is exceeded.

CAUTION

To prevent water damage, the hot

and cold water valves should be

accessible when the washing

machine is in place and should

always be turned off when the

washing machine is not in use.

CAUTION

If installing the washing machine in a

new building or a building in which

the plumbing system was recently

installed or upgraded, flush the lines

before installing the washing

machine to remove any sand, dirt or

residue.

Connection

C Cold water connection and

H Hot water connection

(max. 140 °F / 60 °C)

min.0,4''

(10 mm)

q After the connection,

Turn on the water completely, and

check that connection points are

watertight.

d

CAUTION

d

The connection points are under full

water pressure. Check seal with tap

fully open.