Modifying Control Settings

To change the value of a system function, locate the
function on the IntelliTec Settings Menu and follow the
steps below.

IMPORTANT:

Before making changes to any settings, record the
original values. If the setting changes do not achieve
desired results, return settings to their original val-
ues.

A.

Press and hold the SEL button for 8 seconds.
While still holding the SEL button, press the up
arrow button (

⇑). The LCD Screen will read

DISPLAY.

B.

Release both buttons.

C.

Press the left arrow button (

⇐) to get to the correct

menu (Basic, Advanced, or Storage).

D.

Press the up arrow button (

⇑) to navigate to the

value that needs to be changed.

E.

Press the SET button to enter the edit mode.

F.

Press the up arrow button (

⇑) to change the

setting.

G.

Press the SET button to save the setting and exit
the edit mode.

H.

Press the up arrow (

⇑) and the left arrow (⇐

⇐)

buttons to navigate through the rest of the settings
as needed.

I.

When all changes have been completed, press
the up arrow button (

⇑) from ExitMenu to return to

the current mode display.

4.5

READINGS (SERVICE PERSONNEL

ONLY)

The IntelliTec control continuously monitors and records
temperatures, voltages, amps, and error code details.
Each reading is beneficial to service personnel when
troubleshooting.

DISPLAY READINGS

Following are the readings available under the DISPLAY
menu:

Cabinet

The temperature of the cab is constantly monitored
by the IntelliTec control.

Cycles (count)

This reading counts down the number of cycles in
the current "Serve Mode". The starting value is
dependant upon the Cycles setting on the IntelliTec
control.

°F and amps

Suction line temperature on the freezing cylinder
and drive motor amps are available on the same
screen to assist with setup and troubleshooting.

Aux. Temp (°F)

This reading provides the ambient temperature
around the IntelliTec control board.

Supply V (VAC)

The input voltage is recorded.

ERROR CODE READINGS

The following details are recorded under the ERRCODES
menu for each of the last 25 error codes received:

Err1 (hours)

A timer begins when an error occurs. The timer
records the number of hours since the error
occurred. If power to the machine is interrupted,
the timer will stop until power has been restored.

°F and amps

The suction gas temperature on the freezing
cylinder and the drive motor amps are recorded at
the time of the error.

Aux. Temp (°F)

Ambient temperature of the IntelliTec control board
is recorded at the time of the error.

Str (°F)

The storage temperature is recorded at the time
of the error.

VAC and Mode

The input voltage and mode at which the error
occurred are recorded. Following are descriptions
of each mode:

Mode

Description

0

Start of freezing cycle

1

Compressor and drive motor on

2

Stir Cycle

3

Compressor off

4

"Standby Mode"

5

"Sleep 1 Mode"

6

"Sleep 2 Mode"

7

"Clean Mode"

8

Startup

9

Storage only refrigeration

10

Freezing cycle is shut down

11

Door safety switch triggered

12

High pressure cutout

Up Time (hours)

This value is a record of the total time the machine
has been in service. If power is interrupted, the
timer will stop until power is restored. This timer
does not reset.