beautypg.com

Conducted emi – Cirrus Logic CRD1631-10W User Manual

Page 23

background image

CRD1631-10W

DS1005RD2

23

10. CONDUCTED EMI

Device Under Test: CRD1631-10W-Z

Operating Conditions: NOMINAL

Test Specification: EN55022

Operator Name: JC

Scan Settings (1 Range)

Final Measurement

Detectors: QP

+

, AV

Peaks: 10

Meas Time:

50ms

Acc. Margin: 3dB

Final Measurement Results

Frequencies

Receiver Settings

Start

Stop

Step

Res BW

M-Time

Atten

Preamp

150kHz

30MHz

4.5kHz

9kHz (6dB)

50ms

Auto

Off

Trace

Frequency

(MHz)

Level

(dB

V)

Limit

(dB

V)

Delta Limit

(dB)

Delta Ref

(dB)

Comment

1

PK+ 0.1545 65.04 65.75 -0.71

L1

/

on

2

AV 19.779 47.51 50.00 -2.49

L1

/

on

2

AV 19.833 47.02 50.00 -2.98

L1

/

on

2

AV 19.9095

48.06 50.00 -1.94

L1

/

on

2

AV 19.959 47.49 50.00 -2.51

L1

/

on

2

AV 20.013 47.39 50.00 -2.61

L1

/

on

2

AV 20.0895

47.89 50.00 -2.11

L1

/

on

1 MHz

10 MHz

150 kHz

30 MHz

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

0.0

100.0

dBμV

Limits

55022MQP

55022MAV

Transducer
ENV216

Traces

PK+

AV

Figure 25. Conducted EMI