Conducted emi – Cirrus Logic CRD1631-10W User Manual
Page 23
CRD1631-10W
DS1005RD2
23
10. CONDUCTED EMI
Device Under Test: CRD1631-10W-Z
Operating Conditions: NOMINAL
Test Specification: EN55022
Operator Name: JC
Scan Settings (1 Range)
Final Measurement
Detectors: QP
+
, AV
Peaks: 10
Meas Time:
50ms
Acc. Margin: 3dB
Final Measurement Results
Frequencies
Receiver Settings
Start
Stop
Step
Res BW
M-Time
Atten
Preamp
150kHz
30MHz
4.5kHz
9kHz (6dB)
50ms
Auto
Off
Trace
Frequency
(MHz)
Level
(dB
V)
Limit
(dB
V)
Delta Limit
(dB)
Delta Ref
(dB)
Comment
1
PK+ 0.1545 65.04 65.75 -0.71
L1
/
on
2
AV 19.779 47.51 50.00 -2.49
L1
/
on
2
AV 19.833 47.02 50.00 -2.98
L1
/
on
2
AV 19.9095
48.06 50.00 -1.94
L1
/
on
2
AV 19.959 47.49 50.00 -2.51
L1
/
on
2
AV 20.013 47.39 50.00 -2.61
L1
/
on
2
AV 20.0895
47.89 50.00 -2.11
L1
/
on
1 MHz
10 MHz
150 kHz
30 MHz
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
0.0
100.0
dBμV
Limits
55022MQP
55022MAV
Transducer
ENV216
Traces
PK+
AV
Figure 25. Conducted EMI
- CobraNet (147 pages)
- CS4961xx (54 pages)
- CS150x (8 pages)
- CS1501 (16 pages)
- CS1601 (2 pages)
- CS1601 (16 pages)
- CS1610 (16 pages)
- CRD1610-8W (24 pages)
- CRD1611-8W (25 pages)
- CDB1610-8W (21 pages)
- CS1610A (18 pages)
- CDB1611-8W (21 pages)
- CDB1610A-8W (21 pages)
- CDB1611A-8W (21 pages)
- CRD1610A-8W (24 pages)
- CRD1611A-8W (25 pages)
- CS1615 (16 pages)
- AN403 (15 pages)
- AN401 (14 pages)
- AN400 (15 pages)
- AN375 (27 pages)
- AN376 (9 pages)
- CRD1615-8W (22 pages)
- CRD1616-8W (23 pages)
- AN402 (14 pages)
- AN404 (15 pages)
- CRD1615A-8W (21 pages)
- CS1615A (16 pages)
- CS1630 (56 pages)
- AN374 (35 pages)
- AN368 (80 pages)
- CRD1630-10W (24 pages)
- CS1680 (16 pages)
- AN405 (13 pages)
- AN379 (31 pages)
- CRD1680-7W (31 pages)
- AN335 (10 pages)
- AN334 (6 pages)
- AN312 (14 pages)
- AN Integrating CobraNet into Audio Products (16 pages)
- CobraNet Audio Routing Primer (9 pages)
- Bundle Assignments in CobraNet Systems (3 pages)
- CS2300-01 (3 pages)
- CS2000-CP (38 pages)