1 flyback transformer, 1 electrical specifications – Cirrus Logic CRD1631-10W User Manual
Page 15

CRD1631-10W
DS1005RD2
15
8.1
Flyback Transformer
The flyback transformer stage is a quasi-resonant peak current-regulated DC-DC converter capable of delivering
the highest possible efficiency with constant current output while minimizing line frequency ripple. The auxiliary wind-
ing is used for zero-current detection and overvoltage protection.
Figure 12. Flyback Transformer Schematic
8.1.1
Electrical Specifications
Characteristics conditions:
• Operating temperature range: -25 °C to +120 °C (including coil heat)
Notes:
9. Time = 2sec.
10. Measured across pins 5 and 4.
11. Measured across pins 10 and 9.
12. Measured across pins 3 and 2.
Parameter
Condition
Symbol
Min
Typ
Max
Unit
Flyback Transformer
Electrical Strength
f
operate
=50/60Hz
-
4K
-
V
RMS
Primary Inductance
(Note 10)
f
resonant
=10kHz, 0.3V at 20°C
L
P
-
9.7
-
mH
Primary Leakage Inductance
(Note 10)
f
resonant
=10kHz, 0.3V at 20°C
L
K
-
138
-
H
Primary DC Resistance
(Note 10)
t
DCR
=20°C
-
22.7
-
Secondary DC Resistance
(Note 11)
t
DCR
=20°C
-
0.3
-
Auxiliary DC Resistance
t
DCR
=20°C
-
1
-
144T
#38 AWG
144T
#38 AWG
36T TWR
#29 AWG
Primary
Secondary
5
1
4
10
9
8T
#40 AWG
2
Auxiliary
3