1 measured results, An376 – Cirrus Logic AN376 User Manual
Page 5
AN376
AN376REV2
5
Equation 6 on page 3 is used to calculate the attenuation factor:
Since the RC network attenuates the sinusoidal component by 40%, the resulting AC current in the LEDs is cal-
culated using Equation 10 on page 4:
Therefore the LED string current I
LED
is a 164mA peak-to-peak sinusoidal on a DC offset. For this design, the
typical current ripple is approximately ±33% on the 250mA RMS output current.
2.3.1 Measured Results
The measured output voltage of the CRD1615-8W is 28V at an RMS output current of 250mA. The switching
mode power supply is driving 10 Philips LUMILEDS DS61 LEDs in series. Figure 4 illustrates the attenuation of
the RC filter implemented in the CRD1615-8W. The final ripple current on the LED current, I_LED, is measured
at approximately 170mA peak-to-peak.
H 4
f
line
1
1
754 R
LED
C
OUT
2
+
-------------------------------------------------------------------------
1
1
754 4.5
680
F
2
+
---------------------------------------------------------------------------
1
2.5
--------
=
=
=
[Eq. 12]
I
ripple
I
PK
0.4
205mA 0.4
82mA
=
=
=
[Eq. 13]
Figure 4. CRD1615-8W Measured Results
Notes:
The current to voltage relationship is 100mA:20mV
Current I_LED is representative of the current flowing through the LED string