2 flyback transformer, 1 electrical specifications – Cirrus Logic CDB1611A-8W User Manual
Page 13
CDB1611A-8W
DS1013DB3
13
6.2
Flyback Transformer
The flyback transformer stage is a quasi-resonant peak current-regulated DC-DC converter capable of delivering
the highest possible efficiency with constant current output while minimizing line frequency ripple. The auxiliary wind-
ing is used for zero-current detection and overvoltage protection.
6.2.1
Electrical Specifications
Characteristics conditions:
• Operating temperature range: -25 °C to +120 °C (including coil heat)
Notes:
3. Time = 2s
4. Measured across pins 3 and 4
5. Measured across pins B and A
6. Measured across pins 2 and 1
Parameter
Condition
Symbol
Min
Typ
Max
Unit
Flyback Transformer
Electrical Strength
f
operate
=50/60Hz
-
4K
-
V
RMS
Primary Inductance
f
resonant
=10kHz, 0.3V at 20°C
L
P
13.05
14.5
15.95
mH
Primary Leakage Inductance
f
resonant
=10kHz, 0.3V at 20°C
L
K
-
106
-
H
Primary DC Resistance
t
DCR
=20°C
5.25
7.0
8.75
Secondary DC Resistance
t
DCR
=20°C
-
120
-
m
Auxiliary DC Resistance
t
DCR
=20°C
-
400
-
m
113T
#36 AWG
(0.13 mm)
67 T
# 36AWG
(0.13mm)
10 T
# 36AWG
(0.13mm)
Primary
4
5
3
1
Auxiliary
2
Secondary
10T
#27AWG
(0.35mm)
B
A
Figure 8. Flyback Transformer Schematic