4

WIKA operating instructions level sensors model RMG

13442163.01 06/2010 GB/D/F

1. Functional description

The level transmitter model RMG is used for remote measuring of the

level of liquid media.

It operates according to the float principle with magnetic transmission

in three-wire potentiometer circuit. A reed measuring network (reed

contacts + resistors) built into the slip pipe (5) is actuated by a perma-

nent magnet built into the float (6). This provides a proportional resis-

tance signal for evaluation. Evaluation may take place for example with a

series-connected resistance transmitter.

2. Area of application

Level transmitters serve exclusively for monitoring the level of liquid

media. All materials which come into contact with the media must be

suitably resistant. The medium to be monitored may not be heavily

contaminated. It may not have a tendency to crystallize.

The level transmitters must be operated on safety barriers or an intrinsi-

cally safe control circuit for use in „e“ areas of zone 1 or 2.

3. Assembly

Install WIKA level transmitters according to their model (flange or thread

(3)). Fit a suitable gasket (4) for sealing. Make sure they are installed in

the right position.