Thermowell

Stem

Required safety

clearance

14004105.01 05/2011 GB/D/F/E

WIKA operating instructions model 54, Twin-Temp

11

6. Commissioning, ... / 7. Maintenance and ...

CAUTION!

When using thermowells, please

ensure that the stem does not

touch the bottom of the thermowell

since, due to the different

expansion coefficients of the

materials, the stem may become

buckled at the bottom of the

thermowell.

(Formula for the calculation of the

stem length l

1

see the respective

thermowell‘s data sheet)

7. Maintenance and cleaning

7.1 Maintenance

The combined bimetal thermometer is maintenance-free!

The indicator should be checked once or twice every year. To do this

the instrument must be disconnected from the process and checked

using a temperature calibrator.
Repairs must only be carried out by the manufacturer.

7.2 Cleaning

CAUTION!

Clean the thermometer with a moist cloth.

Wash or clean the disconnected thermometer before

returning it in order to protect personnel and the

environment from exposure to residual media.