beautypg.com

WIKA TR70 User Manual

Page 31

background image

11286700 D/GB/F/E 07/2007

GB

Switching outputs
• Switching function
• Switching rating
• Adjustment
- Set Point
- Reset point

adjustable normally closed (NC) or normally open (NO) contact
100 mA per switching output
Programmable via the display
0.1° steps withhin temperature range
0.1° steps from beginning temperature range until max. set point –0.1°

Analogue output
Signal

Load resistance

4 … 20 mA; 2-wire, programmable in 0.1° steps,
span at least 20 % of the temperature range

Dependent on the supply voltage; the relevant formula is R =

U

Supply

- 7 V

0.022 A

Display

4-digit 7-segment LED display, red, 7.6 mm high

Accuracyt

Switching output, analogue output and Display:
Accuracy of Pt100 + 0.1% of the temperature range

Reproducibility

0.0 %

Electrical connection

4-pin circular plug M12 x 1 with gold-plated contacts

Temperature range
Storage
Ambient
Tk

-30 ... +80 °C
-2 ... +70 °C
0.1 % of measurement range per 10 K

EMV to IEC /
EN 61 326

IEC 61000/4/2 ESD: B
IEC 61000/4/3 HF gestrahlt: A
IEC 61000/4/4 Burst: A
IEC 61000/4/ Surge: A
IEC 61000/4/6 HF Leitungsgebunden: A

Protection class

IP 6 according IEC 29

Weight

ca. 0 3 kg je nach Tauchschaft

Betriebsanleitung / Operating manual / Instructions de service / Instrucciones de uso TR70

31