WIKA operating instructions pressure gauge model 6 per ATEX

3. Specifications ... 5. Transport, packaging and storage

3. Specifications

Pressure limitation

Model 63X.50: Steady:

full scale value

Fluctuating: 0.9 x full scale value

Short time: 1.3 x full scale value

Model 632.51: Steady:

full scale value

Fluctuating: 0.9 x full scale value

Short time: 50 x full scale value

Temperature effect

When the temperature of the measuring system deviates from the reference

temperature (+20 °C): max. ±0.6 %/10 K of full scale value
IP ingress protection

Housing (EN 60529/IEC 60 529)

IP 54 (IP 65 with liquid-filled gauges)
For further specifications see WIKA data sheet PM 06.03, PM 06.06 and the order

documentation.

4. Design and function

Description

„

Nominal size 63, 100 and 160 mm

„

The gauges measure the pressure by means of resilient capsule pressure

elements

„

The measuring characteristics are in accordance with the EN 837-3 standard

Scope of delivery

Cross-check scope of delivery with delivery note.

5. Transport, packaging and storage

5.1 Transport

Check pressure gauge for any damage that may have been caused by transport.

Obvious damage must be reported immediately.
5.2 Packaging

Do not remove packaging until just before mounting.

Keep the packaging as it will provide optimum protection during transport (e.g.

change in installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage

„

Storage temperature: -20 ... +70 °C (optional: -40 … +70 °C)