beautypg.com

WIKA 630.20 User Manual

Page 5

background image

5

WIKA Operating instructions pressure gauges Model 6 with 831 per ATEX

2030660 12/2004 GB/D/F

GB

3. Technical data and use in accordance with intended use

3. Technical data and use in accordance with intended use

Working pressure

Steady:

full scale value

Fluctuating:

0.9 x full scale value

Short time:

1.3 x full scale value (special versions up to 3 × resp.

10 × full scale value)

Pressure connection

T

According to the general technical regulations for pressure gauges,

respectively (i.e. EN 837-2 "Selection and installation recommendations for

pressure gauges").

When screw-fitting the gauges the force required for sealing must not be

applied through the case or terminal box but, using a suitable tool, only through

the spanner flats provided for this purpose at the square of the connector.

Installation with

open-end wrench

Temperature effect

When temperature of the pressure element deviates from reference temperature

(+20 °C): max. ±0.6 %/10 K of true scale value

IP Ingress protection

IP 54 per EN 60 529 / IEC 60 529

(with liquid filling IP 65)

This manual is related to the following products: