beautypg.com

Gb 3. specifications – WIKA R-1 User Manual

Page 14

background image

14

WIKA operating instructions pressure transmitter, model R-1

14026284.01 11/2012 GB/D/F/E

GB

3. Specifications

3.7 Electrical connections

Short-circuit resistance

S

+

vs. 0V

Reverse polarity protection

U

B

vs. 0V

Overvoltage protection

maximum DC 36 V

Insulation voltage

DC 500 V

3.8 Materials

Wetted parts

Sensor and process connection from stainless steel

Non-wetted parts

Case from stainless steel

Electrical connection from highly resistant, glass-fibre reinforced plastic PBT GF 30

3.9 Approvals, directives and certificates
Approvals

cRUus (recognition)

CE conformity

EMC directive 2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (indus-