Kramer Electronics FC-7402 User Manual
Page 9

Using Your FC-7402 SDI to Analog Converter
7
5.1.3
Adjusting Oversampling to x2 (Moving Jumper JMP1)
Setting DIP 4 ON enables oversampling
1
, which provides the picture with a
better S/N ratio. The default is x4 (recommended). However, you can adjust
this factory preset to 2 X OVRSMPL.
To adjust oversampling to x2, do the following:
1.
Set DIP 4 OFF and remove the power cord.
2. Open
the
FC-7402 unit and move Jumper JMP1 to the left (see Figure 4).
3. Close
the
FC-7402 unit, set DIP 4 ON and connect the power cord to the
mains electricity.
Figure 4: Adjusting Oversampling to x2 (Moving Jumper JMP1)
1 When a signal is digitally sampled at frequencies much higher than the NYQUIST frequency. When this method is used, the
noise figure is improved