Linking SDI-AES De-Embedder / SDI-AES Embedder Units

9

6.2 Cascading SDI-AES De-Embedder / SDI-AES Embedder Units

You can cascade up to four interconnected

6809 SDI-AES Embedder units

with up to four interconnected

6808 SDI-AES De-Embedder units

1

to provide

eight streams of AES, each stream containing two digital audio channels (see

Figure 6 and Figure 7).
To cascade four

6809 and four 6808 units, do the following:

1. Connect up to 16 analog audio sources to the analog inputs on an

AES

Audio Router (A/D), and connect each of the eight AES outputs

2

.

2. Connect an SDI source to the SDI IN BNC connector on the

6809 unit # 1

and interconnect

3

the four

6809 units.

3. Connect the SDI OUT BNC connector on

6809 unit # 4 to the SDI IN

BNC connector on

6808 unit # 1, and interconnect

4

the four

6808 units.

4. Connect the two AES OUTPUT BNC connectors on each

6808 unit

5

.

5. On each

6809 / 6808 unit, set the GROUP SELECT dipswitches to

choose the audio group (see section 5.2.1).

6. On each

6809 / 6808 unit, connect a 12V DC power adapter to the power

socket and connect the adapter to the mains electricity

6

.

1 Using a single coax cable (SDI + AES) with a transmission of up to 300m
2 Connect the AES OUTPUT 1 to the AES INPUT A BNC connector, and the AES OUTPUT 2 to the AES INPUT B BNC
connector (6809 unit # 1). Connect the AES OUTPUT 3 to the AES INPUT A BNC connector, and the AES OUTPUT 4 to
the AES INPUT B BNC connector (6809 unit # 2). Connect the AES OUTPUT 5 to the AES INPUT A BNC connector, and
the AES OUTPUT 6 to the AES INPUT B BNC connector (6809 unit # 3). Connect the AES OUTPUT 7 to the AES INPUT
A BNC connector, and the AES OUTPUT 8 to the AES INPUT B BNC connector (6809 unit # 4)
3 Connect the SDI OUT BNC connector on unit # 1 to the SDI IN BNC connector on unit # 2; connect the SDI OUT BNC
connector on unit # 2 to the SDI IN BNC connector on unit # 3; and connect the SDI OUT BNC connector on unit # 3 to the
SDI IN BNC connector on unit # 4
4 Connect the SDI LOOP BNC connector on unit # 1 to the SDI IN BNC connector on unit # 2; connect the SDI LOOP BNC
connector on unit # 2 to the SDI IN BNC connector on unit # 3; and connect the SDI LOOP BNC connector on unit # 3 to the
SDI IN BNC connector on unit # 4
5 On 6808 unit # 1, connect the AES OUTPUT A BNC connector to the AES stream 1, and the AES OUTPUT B BNC
connector to the AES stream 2. On 6808 unit # 2,connect the AES OUTPUT A BNC connector to the AES stream 3, and the
AES OUTPUT B BNC connector to the AES stream 4. On 6808 unit # 3, connect the AES OUTPUT A BNC connector to the
AES stream 5, and the AES OUTPUT B BNC connector to the AES stream 6. On 6808 unit # 4, connect the AES OUTPUT
A BNC connector to the AES stream 7, and the AES OUTPUT B BNC connector to the AES stream 8
6 As an option, you can purchase the Kramer VA-50P 6 Port Universal 12-Volt Power Supply, enabling you to supply power