Appendix B: Y1157A Cable Assembly Instructions

The Y1157A is a 10- pin ribbon connector to 9- pin D- Sub cable kit
which contains materials to build four cables.

The key to building the cables correctly is to understand the
orientation of the socket pins on the distribution boards and the pin
number orientation of the cable connectors. This orientation is shown
in

Figure B- 1

. When using the D- sub connector, always refer to the

pin orientation shown in

Figure B- 1

. Do not use the pin numbers

printed on the part.

Figure B-1 Distribution board socket and Y1157A cable connector Orientation

The steps for building the cables are as follows:

1 Cut the ribbon cable slightly longer than the desired length.

2 Position the D- Sub connector and the ribbon cable connector as

shown in

Figure B- 2

. Route the cable through the connectors,

noting the location of cable pin 1. By convention, pin 1 is indicated
in red (the dark line in the drawing).

Distribution board

Ribbon connector (10-pin)

D-Sub connector (9-pin)

connector (10-pin)