Configuring the Ethernet Port

3

1.1 Setting a Virtual Port

If the control application cannot work with an Ethernet driver, use the Kramer

Virtual port driver as follows:

1. Insert the CD-ROM in the CD-ROM drive, double click the SetKVSP_xx.exe

1

file and follow the on-screen instructions

2

.

The virtual serial port is installed.

2. Run the Virtual Serial Port Manager Application.

The Virtual Serial Port Manager window appears (see Figure 2).

Figure 2: The Virtual Serial Port Manager Window

3. Press the

Add VSP button to add a serial port and type the IP settings

according to the IP address and local port of your

Kramer Machine

3

(see

Figure 3).

1 File names are liable to change from time to time
2 The latest version appears on our Web site at http://www.kramerelectronics.com
3 The factory default IP address is 192.168.1.39 and the factory default local port is 5000