-50 °C to +150 °C

Note: To avoid battery drain, the device will switch itself off after approximately 5 minutes.
• To change the displayed unit, press the Unit Change Button (4)
Note: This device can display readings in either °C or °F.
• To hold the value currently being displayed, press the Hold Button (1). The display will freeze, the

word ‘HOLD’ will be displayed and it will continue to hold that value for approximately 3 minutes

• Whilst the thermometer is in use, pressing the Max/Min Button (3) once will display the lowest

recorded temperature. Pressing the button again will display the maximum recorded temperature

whilst the thermometer has been on

• The thermometer can be used to measure the ambient temperature with the Probe Cover (6)

attached. It can also be used to take internal measurements, by removing the probe cover and

inserting the Probe (7) into an object

WARNING: The probe features a pointy metal tip. Handle with care to avoid puncture wounds and

other kinds of injury.

Maintenance

• Wipe the probe clean with a damp cloth after each use and dry thoroughly
Note: Dirt and debris could affect the accuracy of temperature readings and lead to cross

contamination of materials
• Clean the plastic housing and display with a soft dry cloth only

Storage

• Allow the Probe (7) to cool completely after use with hot materials
• Cover the probe with the Probe Cover (6) for storage
• Store carefully in a secure, dry place out of the reach of children
• Remove the battery if the thermometer is stored for an extended period of time

Disposal

Always adhere to national regulations when disposing of power tools that are no longer functional

and are not viable for repair.
• Do not dispose of batteries and electrical and electronic equipment (WEEE), with household waste
• Contact your local waste disposal authority for information on the correct way to dispose of

batteries and electrical equipment

Remarque : La lecture peut se faire en °C ou en °F
• Pour laisser l’unité actuellement affichée, appuyez sur le bouton de maintien (1). Le mot ‘HOLD’

s’affichera et la lecture de la donnée sera visible pendant environ 3 minutes.

• Pendant l’utilisation du thermomètre, le fait d’appuyer sur le bouton max/min (3) affiche la

température la plus basse enregistrée. En appuyant à nouveau sur ce bouton, la température

maximale enregistrée s’affichera

• Ce thermomètre peut être utilisé pour mesurer la température ambiante. Pour cela il suffit laisser

le cache de la sonde (6). Vous pouvez aussi mesurer la température interne des objets en

enlevant le cache de la sonde et en insérant celle-ci (7) dans l’objet.

Attention : La sonde en métal du thermomètre est pointue et coupante. Manipulez avec précautions

afin de ne pas vous blesser.

Entretien

• Nettoyez la sonde avec un chiffon humide après chaque utilisation et bien la séchez.
Remarque : La saleté et les résidus peuvent affecter la précision de lecture de la température et

engendrer une contamination croisée des matériaux.
• Nettoyez le boitier plastique et l’écran d’affichage avec uniquement un chiffon doux et sec.

Rangement

• Si la sonde est chaude, laissez la refroidir
• Mettez toujours le cache sur la sonde avant de la ranger
• Ranger cet appareil dans un endroit sûr, sec et hors portée des enfants
• Retirez la pile si le thermomètre va être rangé pour une longue période.

Recyclage

Lorsque l’appareil n’est plus en état de fonctionner et qu’il n’est pas réparable, recyclez l’appareil en

accordance avec les régulations nationales.
• Ne jetez pas les outils électriques et autres équipements électriques ou électroniques(DEEE) avec

les ordures ménagères

• Contactez les autorités locales compétentes en matière de gestion des déchets pour vous informer

de la procédure à suivre pour recycler les outils électriques

As part of our ongoing product development, specifications of Silverline products may alter

without notice.

Important Safety Warnings

• This thermometer features a metal probe with a sharp, pointed tip. Handle with care to avoid

puncture wounds and other kinds of injury

• Never carry the device with the Probe (7) exposed and without the Probe Cover (6) in place
• Keep out of the reach of children
• The metal probe can become extremely hot when used on hot objects and substances. DO NOT

touch and DO NOT bring into contact with combustible materials whilst hot

• This device has not been hygienically rated for use with foodstuffs. Do not use as a kitchen

thermometer

Before Use
Inserting the battery

• Remove the battery cover on the back by rotating it a quarter of a turn anti-clockwise
• Insert the battery into the thermometer with the blank unlabelled (minus) side facing inside and

the side labelled ‘+’ visible on the outside

• Replace the cap by lining it up and rotating a quarter of a turn clockwise

Operation

• Press the On/Off Button (2) to switch the thermometer on
• To switch the thermometer off, press the on/off button again

Du fait de l’évolution constante de notre développement produit, les caractéristiques des produits

Silverline peuvent changer sans notification préalable.

Consignes importantes de sécurité

• La sonde en métal du thermomètre est pointue et coupante. Manipulez avec précautions afin de

ne pas vous blesser.

• Ne portez jamais le thermomètre sans le cache de la sonde en place
• Gardez hors de portée des enfants
• La sonde en métal peut devenir extrêmement chaude lorsqu’utilisée avec des objets ou

substances chaudes. Ne touchez pas ou ne mettez pas en contact avec un combustible lorsque

la sonde est chaude.

• Cet appareil n’a pas été évalué au niveau hygiène pour être utiliser avec la nourriture. Ne l’utilisez

pas comme thermomètre de cuisine.

Avant utilisation
Insérer la pile

• Enlevez le couvercle de la pile à l’arrière en lui faisant faire un quart de tour dans le sens

antihoraire

• Insérez la pile dans le thermomètre de sorte que le signe + soit vers l’extérieure.
• Remettez alors le couvercle en place en le mettant en face de l’ouverture et en lui faisant faire un

quart de tour dans le sens horaire

Instructions d’utilisation

• Appuyez sur le bouton marche/arrêt (2) pour mettre l’appareil en marche.
• Pour arrêter le thermomètre, appuyez à nouveau sur le bouton marche/arrêt.
Remarque : pour éviter que la pile s’use, l’appareil s’arrêtera automatiquement après environ 5

minutes.
• Pour changer l’unité d’affichage, appuyez sur le bouton de changement d’unité (4).

868708

7

1

6

2

3

4

5

Product Familiarisation

1. Hold Button

2. On/Off Button

3. Max/Min Button

4. Unit Change Button

5. LCD Display

6. Probe Cover

7. Probe

Se familiariser avec le produit

1. Bouton de maintien

2. Bouton de marche/arrêt

3. Bouton max/min

4. Bouton de changement d’unité

5. Affichage LCD

6. Cache de la sonde

7. Sonde

Specifications

Measuring range: -50°C to 150°C

Units: Celsius and Fahrenheit

Accuracy: 0 - 79.9°C: ±1°C

< 0°C and >80°C: ±2°C

Display type: LCD

Probe length: 110mm

Probe material: Stainless steel

Battery type: LR936, 1.55V

Specifications

Plage de mesure : - 50 °C à 150 °C

Unité : Celsius et Fahrenheit

Précision : 0 – 79,9 °C: ±1 °C

< 0 °C et >80 °C: ±2°C

Affichage : LCD

Longueur de la sonde : 110 mm

Matériau de la sonde : acier inoxydable

CE Declaration of Conformity

The undersigned: Mr Darrell Morris
as authorised by: Silverline Tools
Declares that
Identification code: 868708
Description: Digital Probe Thermometer
Conforms to the following directives and standards:
• EMC Directive 2004/108/EC
• RoHS Directive 2011/65/EU
• EN 61326-1:2006
• EN 61326-2-2:2006
Notified body: Bureau Veritas Shenzhen Co., LTD, Douggan Branch, China
The technical documentation is kept by: Silverline Tools
Date: 15/05/13
Signed:


Director
Name and address of the manufacturer:
Powerbox International Ltd., Boundary Way, Lufton Trading Estate, Yeovil, Somerset,

BA22 8HZ, United Kingdom

Déclaration de conformité CE

Le soussigné : Mr Darrell Morris
Autorisé par : Silverline Tools
Déclare que le produit :
Code d’identification : 868708
Description : Thermomètre à sonde
Est conforme aux directives suivantes :
• Directive sur la compatibilité électromagnétique 2004/108/CE
• Directive RoHS 2002/95/CE
• EN 61326-1:2006
• EN 61326-2-2:2006
Organisme notifié : Bureau Veritas Shenzhen Co., LTD, Douggan Branch, China
La documentation technique est conservée par : Silverline Tools
Date : 15/05/13
Signature :


Directeur général
Nom et adresse du fabricant ou de son représentant agréé :
Powerbox International Ltd.,, Boundary Way, Lufton Trading Estate, Yeovil, Somerset,

BA22 8HZ Royaume-Uni

www.silverlinetools.com

Digital Probe Thermometer
Thermomètre digital à sonde
Digitales Einstichthermometer

Termómetro digital con sonda
Termometro digitale a sonda
Thermometer met sonde

868708_Z1MANPRO1.indd 1

28/05/2013 11:34