Dual coin, Factory preset programs – American Dryer Corp. SL31AD-15 User Manual
Page 51

47
SECTION VIII
FACTORY PRESET PROGRAMS
Unless otherwise specified at the time of ordering, the Phase 3 microprocessor controller (computer) has been
preprogrammed by the factory with the following parameters. Should changes be found necessary, please read
this manual carefully to thoroughly familiarize yourself with the Phase 3 programming characteristics.
Dual Coin
PL01
ºFAr
tInE
Grd
bUZ
Coin
FLS
bCrS
AtIn
Temperature in Fahrenheit
Timed mode
Antiwrinkle guard on
Antiwrinkle guard buzzer (tone) on
Coin(s) required to start
Display will flash in intervals between “FILL”
and “Amount To Start”
Bad coin reset
Accumulative time
PL02
drYL
Dryness level set at 25
PL03
HIº F
180º
PL04
HICd
Temperature - 100º
Time - 2 minutes
PL05
LOº F
120º
PL06
LOCd
Temperature - 100º
Time - 2 minutes
PL07
PPº F
150º
PL08
PPCd
Temperature - 100º
Time - 3 minutes
PL09
LCdE
Left coin denomination - 10
PL10
rCdE
Right coin denomination - 25
PL11
tPLC
Time per left coin - 4 minutes
PL12
AtSt
Amount to start - 25
PL13
AFAt
Amount for additional time - 10
PL14
Adrt
Automatic dry maximum time - 30 minutes
PL15
GdLY
Gont
Antiwrinkle guard off delay - 2 minutes
Antiwrinkle guard on time - 20-seconds
PL16
AGt