beautypg.com

Dual coin, Factory preset programs – American Dryer Corp. SL31AD-15 User Manual

Page 51

background image

47

SECTION VIII

FACTORY PRESET PROGRAMS

Unless otherwise specified at the time of ordering, the Phase 3 microprocessor controller (computer) has been
preprogrammed by the factory with the following parameters. Should changes be found necessary, please read
this manual carefully to thoroughly familiarize yourself with the Phase 3 programming characteristics.

Dual Coin

PL01

ºFAr

tInE

Grd

bUZ

Coin

FLS

bCrS

AtIn

Temperature in Fahrenheit
Timed mode
Antiwrinkle guard on
Antiwrinkle guard buzzer (tone) on
Coin(s) required to start
Display will flash in intervals between “FILL”
and “Amount To Start”
Bad coin reset
Accumulative time

PL02

drYL

Dryness level set at 25

PL03

HIº F

180º

PL04

HICd

Temperature - 100º
Time - 2 minutes

PL05

LOº F

120º

PL06

LOCd

Temperature - 100º
Time - 2 minutes

PL07

PPº F

150º

PL08

PPCd

Temperature - 100º
Time - 3 minutes

PL09

LCdE

Left coin denomination - 10

PL10

rCdE

Right coin denomination - 25

PL11

tPLC

Time per left coin - 4 minutes

PL12

AtSt

Amount to start - 25

PL13

AFAt

Amount for additional time - 10

PL14

Adrt

Automatic dry maximum time - 30 minutes

PL15

GdLY

Gont

Antiwrinkle guard off delay - 2 minutes
Antiwrinkle guard on time - 20-seconds

PL16

AGt

Active Antiwrinkle guard time - 10 minutes