beautypg.com

American Dryer Corp. SL31AD-15 User Manual

Page 42

background image

38

K. PROGRAM LOCATION 08 (PL08)

Perm Press Cool Down Temperature/Time

Summary: Cool down temperature is programmable from a minimum of 100º F (38º C) to a maximum of

190º F (88º C) or from 35º C (95º F) to a maximum of 90º C (194º F). Cool down time is programmable
from 0 to 9 minutes.

(Wait 3-Seconds)

(Temperature Decrease)

(Temperature Increase)

(Time Increase)

(Time Decrease)

PL08

PERM PRESS

PERM PRESS

PPCd

•100•3

HI TEMP

LO TEMP

100•3

PERM PRESS

PL09

LO TEMP

HI TEMP