Igital, Ontroller, Peration – Glastender BLC-3/4-2 User Manual
Page 7

6
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
D
iGitaL
C
ontRoLLeR
o
peRation
Factory Settings
Range of Adjustment
Set Point
Operating
Range†
Minimum Set
Point
Maximum Set
Point
Standard Cooler Setting
BLC
28º F
28º F to 33º F
27º F
32º F
† Adjusting the factory set point will also adjust the operating range by the same amount
The thermostat controller does not have an “OFF”
function. To turn chiller off, the unit must be
unplugged or power to the electrical branch circuit
has to be turned off via a circuit breaker or switch.
To change the set point - push and hold the SET
button for more than two seconds. When the º F
display begins flashing, push the up arrow or down
arrow buttons to adjust the set point to the desired
value.
To save the new set point and return to the tem-
perature display mode - push and release the SET
button or wait ten seconds.
The operating temperature range is preset at the
factory according to the table below and can be
adjusted up or down within the limits shown.
To see the set point - push and immediately release
the SET button. The set point will be displayed.
To return to normal visualization - Push and
immediately release the SET button or wait five
seconds.
The thermostat control probe wire connector may
become disconnected when the electrical compartment
cover and/or grill are removed. This will result in
thermostat P1 code. While the P1 code is flashing the
compressor will cycle 5 minutes on and 5 minutes off
and may cause icing of the evaporator coil. Service
calls to reconnect the probe wiring are not covered by
factory warranty.
Probe wire
connector