Immediately upon arrival, a visual inspection of the carton should be made to determine if there is evidence of damage

in shipment. Following uncrating, make an inspection for any signs of external damage.

2. s

et

-u

p

of

R

emote

G

LyCoL

L

ine

C

hiLLeR

:

Once the survey of the location has been completed to determine the positioning of the remote glycol line chiller and the

connecting draft beer dispensing stations (refer to the specification sheet to be certain that the trunk line will be within

the recommended distance), make the necessary provisions to locate the unit and provide for the electrical services.

The ideal set-up is to mount the glycol line chiller on a proper machine stand that is easily accessible for routine main-

tenance and service.

In less-than-ideal circumstances, it may be necessary to locate the unit on top of the walk-in cooler or on the floor.

NOTE: Do not locate the glycol chiller in the walk-in cooler, as the cold ambient temperature will reduce the

cooling performance of the unit.

NOTE: A minimum of six inches of clearance should be allowed around the entire unit for proper performance.

Additional clearance should be considered for above the unit and in front of the unit for serviceability.

NOTE: When installed above walk-in cooler, ensure air flow is sufficient to maintain 80°F or lower ambient

temperature to maintain rated cooling capacity.

If the unit is located on the floor:

• Ensure the cabinet is sealed to the floor with NSF listed silicon RTV sealant applied around the entire bottom edge

of the cabinet.

• An optional 4" leg set is available as an accessory.

3. e

LeCtRiCaL

h

ook

-u

p

:

Models BLC-1/3, BLC-1/3-E, BLC-1/2, BLC-3/4, & BLC-3/4-2 are supplied with a 20 Amp grounded cord and plug

that connects at the rear of the unit. Models BLC-1/3-2 & BLC-1/2-2 ship as hard wire units and are supplied with a 30

Amp grounded cord only (no plug) that connects at the rear of the unit. A corresponding 20 Amp or 30 Amp grounded

receptacle or junction box, depending on the line chiller model used, must be installed within reach of the unit.

4. G

LyCoL

L

ine

C

onneCtion

:

Typically, glycol recirculating lines are used to transport the glycol in the line chiller to and from the walk-in cooler to be

connected to the glycol lines in the beer line set.

i

nspeCtion

anD

s

et

-u

p

Recirculating Return

Connect your glycol recirculating

line from the beer line set to the

Line Chiller 3/8" barb fitting.

Recirculating Outlet

Connect your glycol recirculating

line from the beer line set to the

Line Chiller 3/8" barb fitting.